Perle IOLAN SDS HL

SPHINX in Europe
DE
  • AT
  • BE
  • DK
  • FR
  • DE
  • IE
  • IT
  • NL
  • ES
  • SE
  • CH
  • UK
Product groups > Device Server > Perle IOLAN SDS HL

Perle IOLAN SDS HL

Device Server for Hazardous Locations (Hazloc)

Perle IOLAN SDS HL
4446_24759.png
4446_24760.jpg
  • PropertiesProperties
  • DescriptionDescription
  • Further InformationFurther Information
  • PDFPDF
  • 4 software selectable RS232/422/485 serial port interfaces
  • Class 1 Division 2 certified for hazardous locations
  • Conformal coated circuit board
  • -40F to +165F (-40C to +74C) extended temperature support
  • 10/100 Ethernet
  • Advanced security features for data encryption, user authentication and event management

The IOLAN SDS HL Device Server is a secure serial to ethernet solution built to operate in hazardous industrial locations ( Hazloc ). Certified with a hazardous area classification as a Class 1 Division 2 device, the IOLAN SDS HL enables safe and reliable operation in locations where volatile flammable gases, flammable liquid–produced vapors, or combustible liquid–produced vapors are handled, processed, or used.

Why IOLAN SDS HL Device Servers are the preferred choice:

  • High performance 66Mhz, 87 MIPS processor for the best performance on the market
  • Class 1 Divison 2 certified for hazardous locations
  • Conformal coating provides protection against moisture, dust and chemicals
  • Operation in environments requiring extended ambient operating temperatures on -40C to +74C (-40F to +165F).
  • TrueSerial® packet technology delivers the most authentic serial connections across Ethernet for serial protocol integrity
  • Indicators for network and serial interfaces for easy troubleshooting
  • Plug & Play installation utility eliminates configuration hassles for all IOLAN´s on your IP network
  • TruePort – Perle’s com/tty redirector for serial based applications operates on Windows, Vista, Linux, Solaris, SCO and Unix
  • FIPS 140-2 – Cryptographic modules meet US Government NIST compliancy
  • Power over serial cable eliminates costs of a separate power installation
  • Next Generation IP support ( IPv6 ) for investment protection and network compatibility
  • Compact and protective solid steel enclosure for tabletop, wall mount or DIN rail mounting
  • Java-free browser access to remote serial console ports via Telnet and SSH
  • Ping watchdog probes enable customers to power cycle equipment with attached Perle RPS power switches in the event of an unresponsive networking gear


Secure Serial to Ethernet Connectivity

The IOLAN SDS HL Device Server enables administrators to securely access remote serial console ports on equipment such as PBX, servers, routers, network storage equipment and security appliances through an IP network. Sensitive data is protected through standard encryption tools such as Secure Shell (SSH) and Secure Sockets Layer (SSL). Access by authorized users is assured via authentication schemes such as RADIUS, TACACS+, LDAP, Kerberos, NIS and RSA Security´s SecurID tokens.

By using encryption technologies, an IOLAN can protect sensitive and confidential data from a serial device before being sent across a corporate Intranet or public Internet. For compatibility with peer encryption devices, all of the major encryption ciphers such as AES, 3DES, RC4, RC2 and CAST128 are fully supported.

Recognized as the most secure method for communicating to remote private networks over the Internet, the IPSec standard provides robust authentication and encryption of IP packets at the network layer of the OSI model. As a standard it is ideal for multi-vendor interoperation within a network providing flexibility and the ability to match the right solution for a particular application.

IOLAN Plug-ins

By choosig a Perle IOLAN Device Server you can rest assured that virtually any device with a serial COM port will operate in conjunction with your desired application exactly as it did when you had it directly connected. In the unlikely event that the Perle IOLAN Device Server does not enable this out of the box, Perle will make it work.

Perle IOLAN Device Servers utilize customer installable "Device Plug-ins" to successfully network devices where other solutions have failed. Request a free engineering consultation now.

Advanced IP Technology

With support for Next Generation IP (IPv6) the IOLAN Serial to Ethernet Device Server range provides organizations with investment protection to meet this rapidly growing standard.

Demand for IPv6, which is compatible with IPv4 addressing schemes, is driven by the need for more IP address. With the implementation and rollout of advanced cellular networks, a robust method is needed to handle the huge influx of new IP addressable devices on the Internet. In fact, the US Department of Defense has mandated that all equipment purchased be IPv6 compatible. In addition, all major Operating Systems such as Windows, Linux, Unix and Solaris, as well as routers, have built-in support for IPv6.

It is therefore important for end users and integrators to select networking equipment that incorporates the IPv6 standard. The IOLAN line with support for IPv6 already built in, is the best choice in serial to Ethernet technology.

Flexible and Reliable Serial to Ethernet Connections

An IOLAN SDS HL Device Server is ideal for connecting serial based COM port, UDP or TCP socket based applications to remote devices. Perle’s TruePort re-director provides fixed TTY or COM ports to serial based applications enabling communication with remote devices connected to Perle IOLAN´s either in encrypted or clear text modes. You can also tunnel serial data between devices across an IP network.

Perle´s Device Management software provides better centralized control of multiple units resulting in maximum uptime for your remote equipment.

All IOLAN SDS HL models have added protection against electrostatic discharges and power surges with robust 15Kv ESD protection circuitry enabling organizations to utilize this solution in the field with confidence.

Lifetime Warranty

All Perle IOLAN SDS HL Serial to Ethernet Device Servers are backed by the best service and support in the industry including Perle´s unique lifetime warranty. Since 1976 Perle has been providing its customers with networking products that have the highest levels of performance, flexibility and quality.

ProdGrafik

Serial Port Access

    Connect directly using Telnet / SSH by port and IP address
    Connect with EasyPort menu by Telnet / SSH
    Use an internet browser to access with HTTP or secure HTTPS via EasyPort Web menu
    Java-free browser access to remote serial console ports via Telnet and SSH
    Ports can be assigned a specific IP address ( aliasing )
    Multisession capability enables multiple users to access ports simultaneously
    Multihost access enables multiple hosts/servers to share serial ports


Accessibility

    In-band ( Ethernet ) and out-of-band ( dial-up modem ) support
    Dynamic DNS enables users to find a console server from anywhere on the Internet
    Domain name control through DHCP option 81
    IPV6 and IPV4 addressing support


Availability

    Primary/Backup host functionality enables automatic connections to alternate host(s)


Security

    SSH v1 and v2
    SSL V3.0/TLS V1.0, SSL V2.0
    SSL Server and SSL client mode capability
    SSL Peer authentication
    IPSec VPN : NAT Traversal, ESP authentication protocol
    Encryption: AES (256/192/128), 3DES, DES, Blowfish, CAST128, ARCFOUR(RC4), ARCTWO(RC2)
    Hashing Algorithms: MD5, SHA-1, RIPEMD160, SHA1-96, and MD5-96
    Key exchange: RSA, EDH-RSA, EDH-DSS, ADH
    X.509 Certificate verification: RSA, DSA
    Certificate authority (CA) list
    Local database
    RADIUS Authentication, Authorization and Accounting
    TACACS+ Authentication, Authorization and Accounting
    LDAP, NIS, Kerberos Authentication
    RSA SecureID-agent or via RADIUS Authentication
    SNMP v3 Authentication and Encryption support
    IP Address filtering
    Disable unused daemons
    Active Directory via LDAP


Terminal Server

    Telnet
    SSH v1 and v2
    Rlogin
    Auto session login
    LPD, RCP printer
    MOTD - Message of the day


Serial machine to Ethernet

    Tunnel raw serial data across Ethernet - clear or encrypted
    Raw serial data over TCP/IP
    Raw serial data over UDP
    Serial data control of packetized data
    Share serial ports with multiple hosts/servers
    Virtual modem simulates a modem connection - assign IP address by AT phone number
    Virtual modem data can be sent over the Ethernet link with or without SSL encryption
    TruePort com/tty redirector for serial based applications on Windows, Linux, Solaris, SCO, HP UX, NCR UNIX and AIX.
    TrueSerial packet technology provides the most authentic serial connections across Ethernet ensuring serial protocol integrity
    RFC 2217 standard for transport of serial data and RS232 control signals
    Customizable or fixed serial baud rates
    Plug-ins allow customer or Perle provided plug-ins for special applications
    Software Development Kit ( SDK ) available
    Serial encapsulation of industrial protocols such as ModBus, DNP3 and IEC-870-5-101
    ModBus TCP gateway enables serial Modbus ASCII/RTU device connection to ModBus TCP
    Data logging will store serial data received when no active TCP session and forward to network peer once session re-established - 32K bytes circular per port


Console Management

    Sun / Oracle Solaris Break Safe
    Local port buffer viewing - 256K bytes per port
    External port buffering via NFS, encrypted NFS and Syslog
    Event notification
    Manage AC power of external equipment using Perle RPS power management products
    Clustering - central console server enables access ports across multiple console servers
    Windows Server 2003/2008 EMS - SAC support GUI access to text-based Special Administrative Console
    Ping watchdog probes enable customers to power cycle equipment with attached Perle RPS power switches in the event of an unresponsive networking gear


Remote Access

    Dial, direct serial
    PPP, PAP/CHAP, SLIP

    HTTP tunneling enables firewall-safe access to remote serial devices across the internet

    Automatic DNS Update
    Utilize DHCP Opt 81 to set IOLAN domain name for easy name management and with Dynamic DNS support , users on the Internet can access the device server by name without having to know its IP address. See Automatic DNS update support for details

    IPSEC VPN client/servers
    Microsoft L2TP/IPSEC VPN client ( native to Windows XP)
    Microsoft IPSEC VPN Client ( native to Windows Vista )
    Cisco routers with IPSEC VPN feature set
    Perle IOLAN SDS/STS and SCS models


OA&M ( Operations, Administration and Management )

    SNMP V3 - read and write, Perle MIB
    Syslog
    Perle Device Manager - Windows based utility for large scale deployments
    Configurable default configuration
    Installation Wizard
    Set a Personalized Factory Default for your IOLANs


Protocols

    IPv6, IPv4, TCP/IP, Reverse SSH, SSH, SSL, IPSec/IPv4, IPSec/IPv6, L2TP/IPSec, CIDR, RIPV2/MD5, ARP, RARP, UDP, UDP Multicast, ICMP, BOOTP, DHCP, TFTP, SFTP, SNTP, Telnet, raw, reverse Telnet, LPD, RCP, DNS, Dynamic DNS, WINS, HTTP, HTTPS, SMTP, SNMPV3, PPP, PAP/CHAP, SLIP, CSLIP, RFC2217, MSCHAP




Hardware Specifications - IOLAN SDS4 HL - 4 port Compact Device Servers - For Hazardous Locations



IOLAN SDS4 HL
Processor MPC852T, 66 Mhz, 87 MIPS
Memory
RAM MB 32
Flash MB 8
Interface Ports
Number of Serial Ports 4
Serial Port Interface Software selectable EIA-232/422/485 on RJ45
Sun / Solaris Sun / Oracle ‘Solaris' Safe - no "break signal" sent during power cycle causing costly server re-boots or downtime
Serial Port Speeds 50bps to 230Kbps with customizable baud rate support
Data Bits 5,6,7,8, 9-bit protocol support
Parity Odd, Even, Mark, Space, None
Flow Control Hardware, Software, Both, None
Serial Port Protection 15Kv Electrostatic Discharge Protection ( ESD )
Local Console Port RS232 on Serial Port
Network 10-base T / 100-base TX Ethernet RJ45
Software selectable Ethernet speed 10/100 Auto
Software selectable Half/Full/Auto duplex
Ethernet Isolation 1.5Kv Magnetic Isolation
Power
Power Supply Options Power via External power 9-30v DC, 4.8 Watts Terminal Block connector Power IN over serial cable
Nominal Inut Voltage 12v DC
Input Voltage Range 9-30v DC
Input IOLAN over Serial 9-30v DC
Typical Power Consumption
@ 12v DC ( Watts )
2.4
Indicators
LEDs Power/Ready
Network Link
Network Link activity
Serial: Transmit and Receive data per port
Environmental Specifications
Heat Output
( BTU/HR )
8.2
MTBF ( Hours )* 118,466
Operating Temperature -40C to 74C, -40F to 165F
Storage Temperature -40C to 85C, -40F to 185F
Humidity 5 to 95% (non condensing) for both storage and operation.
Case SECC Zinc plated sheet metal (1 mm)
Ingress Protection Rating IP40
Mounting Wall or Panel mounting, DIN Rail mounting kit optional
Product Weight and Dimensions
Weight 0.7 Kg (1.6 lbs)
Dimensions 11.3 x 8.1 x 2.8 (cm), 4.4 x 3.2 x 1.1 (in)
Packaging
Shipping Dimensions 25.5 x 16.5 x 6.5 (cm), 10 x 6.5 x 2.6 (in)
Shipping Weight 1.1 Kg (2.4 lbs)
Regulatory Approvals
Emissions FCC Part 15, Subpart B, Class A
CFR47:2003, Chapter 1, Part 15 Subpart B,(USA) Class A
ICES-003, Issue 4, February 2004 (Canada)
CISPR 32:2015/EN 55032:2015 (Class A)
EN61000-3-2 : 2010, Limits for Harmonic Current Emissions
EN61000-3-3 : 2010, Limits of Voltage Fluctuations and Flicker
Immunity CISPR 24:2010/EN 55024:2010
EN61000-4-2: Electrostatic Discharge
EN61000-4-3: RF Electromagnetic Field Modulated
EN61000-4-4: Fast Transients
EN61000-4-5: Surge
EN61000-4-6: RF Continuous Conducted
EN61000-4-8: Power-Frequency Magnetic Field
EN61000-4-11: Voltage Dips and Voltage Interruptions
Safety IEC 60950-1(ed 2); am1, am2 and
EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013
CAN/CSA-C22.2 No. 60950-1-03 and ANSI/UL 60950-1,
First Edition April 1st 2003 (Recognized Component)
Hazardous Locations EN 60079-0:2012+A11:2013, EN 60079-15:2010 and EN 60079-11:2012
ANSI/ISA - 12.12.01 - 2012 Class I and II, Division 2 and
Class III, Division 1 and 2 ( classified ) locations ( UL-1604 )
CSA C22.2 No. 213 - M1987, R2008
ATEX Class 1 Zone 2
Other Reach, RoHS and WEEE Compliant
Directive 2011/65/EU restriction of the use of certain hazardous substances in electrical and electronic equipment and meets the following standard:: EN 50581:2012
CCATS - G168387
ECCN - 5A992
HTSUS Number: 8471.80.1000
Perle Lifetime warranty
Serial Connector Pinout
IOLAN DTE

RJ45Socket

RJ45 Socket


IOLAN RJ45 Socket
Direction RS232 RS485 Full Duplex RS485 Half Duplex RS422
1 right arrow Power In Power In Power In Power In
2 right arrow DCD - - -
3 left arrow RTS TxD+ DATA+ DATA+ TxD+
4 right arrow DSR - -
-
5 left arrow TXD TxD- DATA-
TxD-
6 right arrow RXD RxD+ - RxD+
7
line
GND GND GND GND
8 right arrow CTS RxD- - RxD-
9 left arrow DTR - - -
10 left arrow Power Out Power Out Power Out Power Out

Optional Perle adapters for use with straight thru CAT5 cabling


*Calculation model based on MIL-HDBK-217-FN2 @ 30 °C




TCP

Using RAW TCP Sockets

A raw TCP socket connection which can be initiated from the serial-Ethernet device or from the remote host/server. This can either be on a point to point or shared basis where a serial device can be shared amongst multiple devices. TCP sessions can be initiated either from the TCP server application or from the Perle IOLAN serial-Ethernet adapter.

UDP

Using Raw UDP Sockets

For use with UDP based applications, Perle IOLANs can convert serial equipment data for transport across UDP packets either on a point to point basis or shared across multiple devices.

Console Server

Console Management

For access to remote console ports on routers, switches,etc, Perle IOLAN’s enable administrators secure access to these RS232 ports via inband Reverse Telnet / SSH or out of band with dial-up modems. Perle IOLAN models with integrated modems are available.

COM/TTY

Connect Serial-based Applications with a COM/TTY Port Driver

Serial ports can be connected to network servers or workstations running Perle's TruePort software operating as a virtual COM port. Sessions can be initiated either from the Perle IOLAN or from TruePort.

Tunneling

Serial Tunneling between two Serial Devices

Serial Tunneling enables you to establish a link across Ethernet to a serial port on another IOLAN. Both IOLAN serial ports must be configured for Serial Tunneling (typically one serial port is configured as a Tunnel Server and the other serial port as a Tunnel Client).

Virtual Modem

Virtual Modem

Enables the serial-Ethernet adapter to simulate a modem connection. When connected to the IOLAN and initiates a modem connection, the IOLAN starts up a TCP connection to another IOLAN serial-Ethernet adapter configured with a Virtual Modem serial port or to a host running a TCP application.





Ordering Information

Available Module
IOLAN SDS4 HL Device Server Class 1 Division 2 Certified, Conformal Coating, 4 X RJ45 connectors,
software selectable EIA232/422/485 interfaces, 10/100 Ethernet,
advanced data encryption, user authentication and event management security features included, IPv6, COM port redirector, 15kv ESD, Extended temperature



Customers who viewed this item also viewed
Accept all Reject Configure

This website uses cookies to provide the best possible experience. More information.